STAVITRODE A 74

STAVITRODE A 74

DESCRIPTION & APPLICATIONS :

A basic coated hardfacing electrode usable in every position, for parts that suffer impact, compression and abrasive wear. It provides anti-wear protection on carbon steels and manganese steels.

Used for hardfacing and repairing ploughshares, crusher jaws, cutting tools, dipper teeth, bucket teeth and screw conveyors.

Welding technique: hold the electrode nearly vertical and keep the arc short; if required, re-dry for 2 hours at 300°C. Where the base is prone to cracking, put down a buffer layer of NiMnCr first. Low alloyed, high carbon tool steels need preheating anywhere from 200 - 400°C, depending on composition and thickness. After surfacing, let the part cool slowly in still air.

UNIQUE FEATURES :

  • Resists wear, abrasion, impact and compression.
  • Hardfacing in all positions, giving 60 - 63 HRC without treatment.
  • The basic coating yields a tough deposit that resists cracks.
  • Current: AC (50 V OCV) or DC (+).

Product details

KEY SPECIFICATIONS :

C Si Mn Cr V Mo B
0.50 1.00 1.00 8.50 1.80 1.50 0.20

ALL WELD METAL MECHANICAL PROPERTIES (TYPICAL) :

Hardness (HRC)
60 - 63 (without treatment)

RECOMMENDED WELDING CURRENT :

Diameter (mm) Current (A)
3.15 90 - 120
4.00 140 - 170
5.00 180 - 210

Frequently Asked Questions

What is STAVITRODE A 74 used for?

STAVITRODE A 74 is a basic coated, all position hardfacing electrode for anti-wear work on carbon and manganese steels, covering hardfacing and repair of screw conveyors, bucket teeth, dipper teeth, cutting tools, crusher jaws and ploughshares.

How hard is the STAVITRODE A 74 deposit?

Typically 60 - 63 HRC with no treatment, and it resists impact, compression and abrasive wear.

What preheat does STAVITRODE A 74 require?

A buffer layer of Ferrowork NiMnCr is recommended on crack-sensitive materials. Low alloyed, high carbon tool steels have to be preheated to 200 - 400°C depending on composition and thickness, and cooled slowly in still air after surfacing.

What amperage should I set for STAVITRODE A 74?

Set 90 - 120 A for 3.15 mm, 140 - 170 A for 4.00 mm and 180 - 210 A for 5.00 mm, on AC (50 V OCV) or DC (+). If necessary, re-dry at 300°C for 2 hours.

Let’s find your welding solution.

Share your requirements. We’ll help you take the next step.

Your details are used only to respond to your enquiry. Privacy Policy

Prefer to call? +91-9319198528

Contact Stanvac

Quick enquiry

Tell us what you need. Our team will be in touch.

By submitting, you agree to be contacted about your enquiry. Privacy Policy.